RTCASMCU startup failure Monitor

  • ID:  Microsoft.LS.2015.Monitoring.UnitMonitor.PairedEvent.AppSharingConf.ASMCU_E_SERVICE_FAILED_TO_START
  • Description:  RTCASMCU startup failure
  • Target:  Application Sharing Component
  • Enabled:  Yes

Operational States

Name State Description
Success state for Monitor 'RTCASMCU startup failure' Success  
Error state for Monitor 'RTCASMCU startup failure' Error  

Alert Details

Monitor State Message Priority Severity Auto Resolution
Error state for Monitor 'RTCASMCU startup failure' (Error) [Skype] The Application Sharing Server failed to start. Medium Critical Yes

Run As Profiles

Name
Default

Monitor Knowledgebase

Summary

The Application Sharing Server failed to start.

Causes

The failure may be due to configuration issues, or internal errors requiring a restart. Please check event detailed logs for one or more of the following events: ASMCU_E_SIP_LISTENING_PORT_INVALID: If this event has occurred the Application Sharing Server should be restarted to restore service. ASMCU_E_CERT_NOT_CONFIGURED: If this event has occurred, then the certificate for Application Sharing Server should be checked for validity and corrected before attempting a restart of the service.

Resolutions

Restart the Application Sharing Server after correcting either or both of the above issues and verify that it starts normally to restore availability.

External References
This monitor does not contain any external references.

See Also for Lync Server 2015 Monitoring Management Pack


Downloads for Lync Server 2015 Monitoring Management Pack