RTCASMCU - Focus Connectivity Monitor

  • ID:  Microsoft.LS.2015.Monitoring.UnitMonitor.PairedEvent.AppSharingConf.ASMCU_E_SIP_FAILED_FOCUS_CONNECTION
  • Description:  RTCASMCU - Focus Connectivity
  • Target:  Application Sharing Component
  • Enabled:  Yes

Operational States

Name State Description
Success state for Monitor 'RTCASMCU - Focus Connectivity' Success  
Error state for Monitor 'RTCASMCU - Focus Connectivity' Error  

Alert Details

Monitor State Message Priority Severity Auto Resolution
Error state for Monitor 'RTCASMCU - Focus Connectivity' (Error) [Skype] The Application Sharing Server cannot communicate over SIP to the Skype for Business Server 2015 Front End Server. Medium Critical Yes

Run As Profiles

Name
Default

Monitor Knowledgebase

Summary

The Application Sharing Server cannot communicate over SIP to the Skype for Business Server 2015 Front End Server.

Causes

The Application Sharing Server cannot communicate with the Skype for Business Server 2015 Front End Server over SIP due to network connectivity issues or unavailability of the Skype for Business Server 2015 Front End Server. This condition prevents setting up new conferencing sessions and is disruptive and potentially fatal for existing conferencing sessions.

Resolutions

Resolve network connectivity issues between the Application Sharing Server and the Skype for Business Server 2015 Front End.

External References
This monitor does not contain any external references.

See Also for Lync Server 2015 Monitoring Management Pack


Downloads for Lync Server 2015 Monitoring Management Pack

AZURE OPTIMIZATION ASSESSMENT GET STARTED
MIGRATION TO AZURE GET STARTED
SYSTEM CENTER MIGRATION TO AZURE GET STARTED
MIGRATION TO AZURE FOR SQL AND WINDOWS 2008 GET STARTED