Registrar: Failed to assign primary front-end for all users Monitor

  • ID:  Microsoft.LS.2015.Monitoring.UnitMonitor.PairedEvent.Registrar.ES_E_FABRIC_PLACEMENT_FAILED
  • Description:  Registrar: Failed to assign primary front-end for all users
  • Target:  Registrar Component
  • Enabled:  Yes

Operational States

Name State Description
Success state for Monitor 'Registrar: Failed to assign primary front-end for all users' Success  
Error state for Monitor 'Registrar: Failed to assign primary front-end for all users' Error  

Alert Details

Monitor State Message Priority Severity Auto Resolution
Error state for Monitor 'Registrar: Failed to assign primary front-end for all users' (Error) [Skype] Server is being shutdown because fabric pool manager could not complete initial placement of users. Medium Critical Yes

Run As Profiles

Name
Default

Monitor Knowledgebase

Summary

Server is being shutdown because fabric pool manager could not complete initial placement of users.

Causes

This can happen if insufficient number of Front-Ends are available in the Pool.

Resolutions

Ensure that all the Front-Ends configured for this Pool are up and running. If multiple Front-Ends have been recently decommissioned, run Reset-CsPoolRegistrarState -ResetType QuorumLossRecovery to enable the Pool to recover from Quorum Loss and make progress.

External References
This monitor does not contain any external references.

See Also for Lync Server 2015 Monitoring Management Pack


Downloads for Lync Server 2015 Monitoring Management Pack

AZURE OPTIMIZATION ASSESSMENT GET STARTED
MIGRATION TO AZURE GET STARTED
SYSTEM CENTER MIGRATION TO AZURE GET STARTED
MIGRATION TO AZURE FOR SQL AND WINDOWS 2008 GET STARTED